Radiation Safety Report 

The executives at Acme Manufacturing Co. were impressed by your first report, and they have asked you and BSCI to return for more work. BSCI has been contracted by Acme Manufacturing Co. to conduct a study to determine employee exposures to radiation. In addition, your company has been contracted to determine the effectiveness of engineering controls, including shielding. After conducting a field assessment, prepare a written report for Bob Sanders (CSP) to present to the Board of Directors. During your field investigation, you find the following field observations: 

Test Equipment and Repair Facility 

The company has an on-site test equipment and repair facility. Much of the test equipment contains a radiation source. Normal practice inside the facility is to limit the time of exposure of employees working on this equipment as a method of control. However, the company is looking at the possibility of installing lead shields or increasing the distance from the source, thus increasing employee time working on equipment. Based on the following information determine the employee’s exposure:  

Location

Employee

Distance (Initial)

Distance (Proposed)

Intensity (Initial)

Intensity at proposed distance

Bench #3

Rita Ray D'Ashun

0.5 ft.

2 ft.

110 mrem/h

Unknown

Bench #5

Robert Long

1 ft.

3 ft.

137 mrem/h

Unknown

Bench #6

Paul Row

0.75 ft.

1.5 ft.

102 mrem/h

Unknown



Based on this information, determine the employee’s actual exposure rate to the radiation source. Show your work (either in the report or as an appendix). 

The second option under consideration is to install lead shields in order to reduce the employee’s dose rate. Using the information provided in the table above, determine the intensity at the same distances listed above if a 5 cm lead shield was placed between the source and the detector. [µ for lead, (662 keV gamma ray) = 1.23 cm-¹]  

Radar Testing Facility 

As part of your assessment, you have been asked to evaluate the estimated power density levels for both near and far fields. When there is no gain listed in the problem, always defer to a gain of 10. Recall that 1 watt = 1,000,000 µW(microwatts). You have conducted your assessment and measurements with the following data: 

Location

Diameter (cm)

Antenna Power (watts)

Distance (r) from Antenna (cm) 

Power Density (Near Field) (µW/cm²)

Power Density (Far Field) (µW/cm²)

Radar Unit #1

48 in

50,000

150 ft.

   

Radar Unit #2

26 cm

110,000

150 ft.

   



Laser Laboratory 

Acme Manufacturing is currently considering constructing a laser laboratory, which will contain Class III, IIIA, and IIIB lasers. Identify the safety control measures that the client must consider before proceeding to the design phase of the project.  

Respond to the details in each section, and format your report in APA style. Include at least each of the following in your report for this unit: 

  • Introduction-briefly describe why the studies were performed (why you started the study).
  • Report details-briefly discuss the details of the scenario (what you found from the study).
  • Conclusions and recommendations-briefly describe your recommendations based on your findings (what you recommend to resolve any deficiencies).
  • Appendix-Measurements and calculations (show your work).
  • At least one page (double-spaced) in length (not including the reference page and appendices).

Prepare your report in a word-processing application (i.e., Word) using APA formatting for all references and in-text citations.

 

Essay Sample Content Preview:

OSH4308 UNIT 3 ASSIGNMENT
Name

OSH 4308 UNIT 3
Instructor
Date
Introduction
In the radiation safety report, Acme Manufacturing needs to evaluate employee exposures to radiation and to do this, there is focus on a test equipment, repair facility, radar testing facility and consider laser safety control measures in the laser laboratory. The laser safety control measures are necessary to minimize the risk that laser devices can generate.
Details of the scenario Test Equipment and Repair Facility
Formula: I2= I1 (d12/d22)
Location

Employee

Distance (Initial)

Distance (Proposed)

Intensity (Initial)

Intensity at proposed distance

Bench #3

Rita Ray D'Ashun

0.5 ft.

2 ft.

110 mrem/h

6.875 mrem/h

Bench #5

Robert Long

1 ft.

3 ft.

137 mrem/h

15.22 mrem/h

Bench #6

Paul Row

0.75 ft.

1.5 ft.

102 mrem/h

25.50 mrem/h

With shield
Formula: I= Ioe-µx
When calculating the intensity at the proposed distance with the lead shield, the linear absorption coefficient of lead, which is 1.23cm-1 is considered in the calculation. Acme Manufacturing Co proposed to install the lead shielding to reduce the dose rate.
Location

Employee

Distance (Initial)

Distance (Proposed)

Intensity (Initial)

Intensity at proposed distance

With Shield

Bench #3

Rita Ray D'Ashun

0.5 ft.

2 ft.

110 mrem/h

6.875 mrem/h

0.2347 mrem/h

Bench #5

Robert Long

1 ft.

3 ft.

137 mrem/h

15.22 mrem/h

0.2923 mrem/h

Bench #6

Paul Row

0.75 ft.

1.5 ft.

102 mrem/h

25.50 mrem/h

0.2176 mrem/h

Radar Testing Facility
Location

Diameter (cm)

Antenna Power (watts)

Distance (r) from Antenna (cm) 

Power Density (Near Field) (µW/cm²)

Power Density (Far Field) (µW/cm²)

Radar Unit #1

48 in (121.92 cm)

50,000

150 ft. (4,572 cm)

17,130

1.9 W/cm²)

Radar Unit #2

26 cm

110,000

150 ft. (4,572 cm)

828,734

4.19 W/cm²

There are various testing fields to test the radars and the two radar units gave different diameters and antenna power. Power density depends on power and distance. In the radar testing calculations, 48 inches are the same as 121.92 centimeters and 150 ft is equal to 4572 cm they are converted to the same parameters when calculating the power density.
Laser laboratory
For the Class III, IIIA, and IIIB lasers, the Nominal Eye Hazard Distance (NOHD) for a given laser, commonly known by its acronym is the distance at which radiation exposure that is the same as the appropriate Maximum Permissible Exposure (MPE) for the eye...